FREE SHIPPING, FAST DELIVERY! Dismiss

EASY SELECTOR

  • CALL US
  • +1 (786) 613-5872
  • EMAIL US
  • info@pumpmarket.us
  • CALL US
  • +1 (786) 613-5872
  • EMAIL US
  • info@pumpmarket.us
  • CALL US
  • +1 (786) 613-5872
  • EMAIL US
  • info@pumpmarket.us

Gasoline Self-Priming Motor Pump with KOHLER Engine SH 265 – 6.5 HP – JBA265/A22B2

5/5

Gasoline Self-Priming Motor Pump with KOHLER Engine SH 265 – 6.5 HP – JBA265/A22B2

------

$3,617.99

Add to Cart

Free Delivery

Estimated 3-5 business days

Note: If This is a heavy item (over 130 lbs) Forklift or Dock Door is required at delivery location. Otherwise Please Request Liftgate service from here: Hand Point Down SVG Vector

This series of electric centrifugal self-priming pumps has the characteristics to have the prime made by means of the emulsion air-liquid. The air of the suction piping is sucked inside the pump body by the depression created by the rotating impeller, therefore it emulsifies with the liquid contained into the pump body.

Applications

The centrifugal self-priming pumps series JCS have been designed to be flanged (or through a flexible coupling) to diesel or gasoline engines and electrical motors. These groups are then suitable for heavy duty application with solids handling, for this series of pumps are the following:

  • Building industry: Drainage of excavation sites, dewatering of floods. Water transfer to/from tankers.
  • Treatment: Transfer of dirty and sewage waters, emptying of domestic or industrial drain wells.
  • Ship industry: Bilge dewatering, washing, water transfer.
  • Civil industry: Transfer of muddy, chemical liquids with solids and particles in suspension. Fire-fighting. Sewerage system drainage.
  • Agriculture: Irrigation at low and middle pressure head.

The emulsion air-liquid is pushed into the delivery channel where the air, which is lighter, gets separated and gets out from the delivery piping; the liquid, which is heavier, returns into circulation. Once the pump gets rid of all the air from the suction piping, the pump starts and it works as a normal centrifugal pump, therefore the pump can work also with a mixture of air-liquid. There is a non-return valve fitted to the discharge side which enables a small quantity of liquid to be retained in the pump body thus allowing an automatic prime and suction lift to any application. This eliminates the need to prime the pump at each start up.

Pump Construction

  • Pump body, impeller, pump support and inlet, in cast iron
  • Non return valve in nitrile rubber and steel
  • Impeller in cast iron
  • Mechanical seal in carbon ceramic (upon request tungsten/carbide)
  • Rotor shaft in stainless steel fitted with seal bearings
  • Totally enclosed fan cooled motor (TEFC)
  • Single phase motors with a built in thermal overload protection on request, the capacitor is permanently in circuit
  • Winding Insulation to class F

Pump Technical Data

Model JBA265-A22B2
Brand JMS
Manufacturer’s Warranty 1 year Limited Warranty
Impeller Material Cast Iron
Port Size (in.) 2″
Max Flow (GPH) 10440
HP 6.5
Motor Kohler gasoline engine SH265
Working Range @ 73 ft. > 1620 GPH
@ 18 ft. > 10440 GPH
Max. Suction Lift (ft.) 17
Max. PSI 31.9
Suction Port (in.) 2″
Discharge Port (in.) 2″
Self-Priming Yes
Start Recoil
Portable Yes – 2 Wheels Trolley with Handles

Pump Performance Curve

Model Solids Handling Impeller Diameter Number of Blades
Inch Inch
JBA265-A22B2 Ø 0.9 Ø 4.3 7

Engine Performance Curve

Model Command Pro CH270
Type 4-cycle, gasoline, OHV, cast iron cylinder liner, aluminum block
Gross Power @ RPM Max. hp (Kw) 7 (5.2) @ 4000
Displacement cu in (cc) 12.7 (208)
Bore inch 2.8
Stroke inch 2.1
Peak Torque @ RPM ft-lb (nm) 10.5 (14.2) @ 3000
Compression Ratio 8.8:1
Dry Weight (Recoil Start) lb 38.7
Oil Capacity gallons 0.6
Fuel Capacity gallons 4.2
Lubrication Splash
Dimension Length (L) inch 10.3
Width (W) inch 15.2
Height (H) inch 15.1
Crankshaft Height inch 4.2

Engine Dimensions (mm)

Installation

Upon installation always prime the pump body first before start up. Pump must be installed always in the horizontal position.